The hybrid-beamslab (HYB-B) COOL is built up of the concrete layer above and wooden beams below. Cooling and heating pipes are already installed in the concrete level at the factory. These are simply joined together on site via a junction box integrated in the element.

HYB-B COOL in detail

Discover the hybrid-beamslab COOL in detail

Key data

Hybrid-Balkendecke Cool, HYB-B COOL
B
Element width up to 300.00 cm
A
Beam spacing (center-to-center) variable
H
Element height
HB, BB
Height of the beam, width of the beam
HC
Concrete thickness variable
K
Active cooling surface
Wood quality
GL24h - GL32h
Concrete quality
C30/37

Extract from the table of values

Other combinations and sizes are of course also possible!
Austria and Germany

Single span girder, B=250.00 cm, HB= 10.00 cm, concrete C30/37, wooden frame GL24h, A= 83.33 cm

Utilisation class, load and partition wall surcharge

 

span [m]

 

beam dimension [cm]

BR/HR

total thickness [cm]

H

mass per unit area [kg/m²]

 

Office building

(utilization class: B2/q=3.0 kN) incl. 2.0 kN floor construction and 1.0 kN partition wall surcharge

7.0024/2434.00280.00
7.5024/2838.00285.00
8.0024/3242.00290.00
8.5024/3646.00295.00
9.0024/3646.00300.00

Residential building/hotel

(utilization class: A1/q=2.0 kN) incl. 2.0 kN floor construction and 1.0 kN partition wall surcharge

7.0024/2434.00280.00
7.5024/2838.00285.00
8.0024/3242.00290.00
8.5024/3246.00295.00
9.0024/3646.00300.00

Ceiling cooling

Installation spacing 
[mm]
room temperature
[°C]
cooling performance 
[W/m²]
Supply temperature 
[°C]
Return temperatur
[°C]
10025681519
15025591519

 

 

Ceiling heating

Installation spacing 
[mm]
room temperature
[°C]
heating performance 
[W/m²]
Supply temperature 
[°C]
Return temperatur
[°C]
10022864035
15022784035

 

 

Possible combinations

OBERNDORFER double wall
Hohlwand-Hybrid-Balkendecke-Detail
Timber-frame
Holzriegel-Hybrid-Balkendecke-Detail
Cross Laminated Timber
Brettsperrholz-Hybrid-Balkendecke-Detail
DELTABEAM Slim Floor
Deltabeam-Hybrid-Balkendecke-Detail
Bricks
Ziegel-Hybrid-Balkendecke-Detail

Characteristics

Cradle to Cradle requirements fulfilled
Low element weight – more m2 on 1 truck
Building services can be integrated
Can be moved without support
Reduced Weather risk
Fast assembly
Dry assembly
Selectable visibility qualities (industrial to residential)

Contact

Start into the future of construction with us

Together we will talk about your ideas and our solutions for your project.
We look forward to your inquiry!